Описание

Function Safety module for elevator control
Cat. / PL according to EN ISO 13849-1 4/e
SIL CL according to IEC/EN 62061 3
1- / 2-channel 1, 2
Output contacts max. 3 s, 1 o
Thermal current Ith max. 2 A
Cross fault detection +
Nominal voltage DC +
Nominal voltage AC +
Connection PS/PC
Width 22,5 mm
Type LG 5925/034
According to- Performance Level (PL) e and category 4 to EN ISO 13849-1- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL) 3 to IEC/EN 61508- Directive 2014/33/EU for elevators Output: 3 NO contacts, 1 NC contact Single or 2-channel operation Line fault detection on On-button Manual restart or automatic restart, switch S2 With or without cross fault monitoring in the loop, switch S1 LED indicator for state of operation LED indicator for channel 1 and 2 Degree of protection IP40, can be mounted in cabinets and installationswith lower degree of protection without additional measures(depending on ambient conditions) Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),DIN 46 228-1/-2/-3/-4 or2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3 As option with pluggable terminal blocks for easy exchange of devices- with screw terminals- or with cage clamp terminals Width 22.5 mm''